The ResMed Airsense 11 is a popular CPAP machine that offers a variety of features to make sleep apnea therapy more comfortable and effective. One of these features is the auto humidity setting, which automatically adjusts the humidity level of the air you breathe to help reduce dryness and irritation. If you’re not sure how to turn on the auto humidity setting, follow these simple steps.
First, make sure that your Airsense 11 is turned on. Then, press the “Settings” button on the front of the machine. From the Settings menu, select the “Humidification” tab. On the Humidification tab, you will see an option for “Auto Humidity.” Simply select this option and press the “OK” button. The Airsense 11 will now automatically adjust the humidity level of the air you breathe based on the ambient temperature and humidity.
Using the auto humidity setting can help to reduce dryness and irritation, which can make CPAP therapy more comfortable. It can also help to improve the effectiveness of your CPAP therapy by reducing the amount of air leakage that occurs. If you’re not sure whether the auto humidity setting is right for you, talk to your doctor. They can help you determine the best settings for your individual needs.
Enabling Auto Humidity on Your AirSense 11 Device
To enjoy the benefits of automatic humidity control with your ResMed AirSense 11 device, follow these simple steps:
1. Access the Clinical Menu
A. Power on your AirSense 11 device.
B. Press the Home button.
C. Scroll down and select the “Clinical” option using the navigation wheel.
D. Enter the Clinical Menu password. The default password is “4191.”
E. Navigate to the “Humidifier” tab using the navigation wheel.
F. Scroll down to the “Humidity Control Mode” option.
G. Select “Auto” using the navigation wheel.
Additional Instructions for Detailed Setup:
Option | Description |
---|---|
Set Fixed Level | Adjust the humidity level manually using the navigation wheel. |
Heated Tube Only | Disable humidification, leaving only the heated tube to warm the air. |
Auto | Enable automatic humidity control, with the device adjusting the humidity level based on your breathing patterns and ambient conditions. |
Navigating the MyAir App or Device Interface
Accessing the MyAir App
To access the MyAir app, you can download it from the App Store (for iOS devices) or Google Play (for Android devices). Once installed, launch the app and create an account if you don’t already have one. Sign in to your account and connect your Airsense 11 device via Bluetooth.
Device Interface
If you prefer to navigate the settings from the device itself, you can find the auto humidity option in the Device Settings menu. Use the navigation buttons on the device to scroll through the options until you find “Device Settings.” Select this option and press the OK button. Within the Device Settings menu, navigate to the “Humidity” setting and use the navigation buttons to toggle between the available humidity options, including “Auto.” Press the OK button to confirm your selection.
Auto Humidity Setting
When you select the auto humidity setting, the device will automatically adjust the humidity level based on several factors, such as the ambient temperature, room temperature, and your breathing patterns. This setting aims to provide optimal comfort by preventing both dry mouth and excessive humidity in the mask.
Auto Humidity Setting |
---|
Adjusts humidity level based on ambient temperature, room temperature, and breathing patterns |
Prevents dry mouth and excessive humidity |
Provides optimal comfort |
Selecting the Humidity Level
After selecting the “Auto Humidity” setting, you need to choose the desired humidity level. The CPAP device will maintain the humidity at this level, providing a more comfortable therapy experience. Here are the steps involved:
1. Access the Menu
With the CPAP device is powered on, press the “Menu” button on the control panel. Navigate through the menu options using the arrow buttons.
2. Find Humidity Settings
Locate the “Humidity Settings” or “Moisture Settings” option in the menu. Use the arrow buttons to scroll to this setting.
3. Set the Humidity Level
Depending on your preferences and the CPAP model, you may have various humidity level options to choose from. Common humidity levels range from 0% to heated, or fully humidified. You have the flexibility to adjust the humidity level to suit your comfort and needs.
Here’s a table summarizing the humidity level options available on common CPAP models:
CPAP Model | Humidity Level Options |
---|---|
ResMed Airsense 11 | 0%, 1-8, Auto, Heated |
Philips DreamStation 2 | Off, 1-5, Auto, Heated |
Breeze Freedom | 0%, 1-8, AutoSet, Heated |
Customizing Humidity Settings
The Airsense 11 allows you to customize the humidity level to suit your comfort preferences. Here’s how to adjust the settings:
1. Enter the Menu
Press the “Menu” button on the device.
2. Navigate to “Settings”
Use the navigation buttons to scroll down and select “Settings.” Press the “OK” button to enter.
3. Choose “Humidifier”
From the Settings menu, scroll down and select “Humidifier.” Press the “OK” button to access the humidifier settings.
4. Set the Humidity Level
The Airsense 11 offers three humidity levels:
Level | Description |
---|---|
Auto | Automatically adjusts the humidity level based on the ambient temperature and humidity. This is the recommended setting for most users. |
Fixed | Maintains a constant humidity level regardless of the ambient conditions. You can manually adjust the humidity level from 1 to 8. |
Off | Turns off the humidifier. |
To set the humidity level, select the desired option and press the “OK” button.
Understanding the Benefits of Auto Humidity
Auto humidity adjusts the humidity level in the humidifier chamber based on the ambient temperature and the user’s breathing patterns. This provides several advantages:
- Optimal Comfort: Auto humidity maintains a comfortable humidity level, preventing dryness or over-humidification, which can lead to discomfort or irritation.
- Improved Sleep Quality: A properly humidified environment promotes restful sleep by reducing congestion and dryness, which can disrupt sleep patterns.
- Reduced Condensation: Auto humidity helps minimize condensation on the mask and tubing, improving the overall user experience and reducing the risk of mask leaks.
- Enhanced Therapy: Optimal humidity levels can enhance the effectiveness of CPAP therapy by reducing airway resistance and improving gas exchange.
5. Personalized Humidity Control
Auto humidity offers personalized humidity control. The device analyzes the user’s breathing patterns and ambient temperature to determine the optimal humidity level. This level can be further adjusted within a range to suit individual preferences. The precise humidity control enhances the user’s comfort and ensures that the humidifier provides the desired level of humidification.
Temperature Range (°C) | Relative Humidity Range (%) |
---|---|
10–20 | 30–45 |
20–25 | 35–50 |
25–30 | 40–55 |
The table indicates the recommended relative humidity range for different ambient temperature ranges. Auto humidity automatically adjusts within these ranges to maintain optimal comfort and therapy effectiveness.
Maintaining Optimal Comfort Levels
Using a CPAP machine can be an effective way to improve your sleep and overall health. However, if the settings are not adjusted correctly, it can lead to discomfort and even exacerbate your sleep problems.
One of the most important settings to adjust is the humidity level. The ideal humidity level will vary from person to person, but it is generally recommended to set it between 30% and 60%. If the humidity level is too low, it can cause your nose and throat to become dry and irritated. This can lead to discomfort and even make it more difficult to breathe.
If the humidity level is too high, it can cause condensation to build up in the mask. This can make the mask uncomfortable to wear and can also lead to skin irritation.
Adjusting the Humidity Setting
To adjust the humidity setting on your Airsense 11 CPAP machine, follow these steps:
1. Press the “Menu” button on the front of the machine.
2. Use the arrow keys to navigate to the “Climate Control” menu.
3. Press the “Enter” button.
4. Use the arrow keys to navigate to the “Humidity Level” setting.
5. Press the “Enter” button.
6. Use the arrow keys to adjust the humidity level to the desired setting.
7. Press the “Enter” button to save the setting.
Tips for Choosing the Right Humidity Setting
The following tips can help you choose the right humidity setting for your CPAP machine:
- Start with the lowest humidity setting and gradually increase it until you find a setting that is comfortable for you.
- If you experience dry nose or throat, try increasing the humidity level.
- If you experience condensation in the mask, try decreasing the humidity level.
- Different climates may require different humidity settings. For example, you may need to use a higher humidity setting in a dry climate than in a humid climate.
If you have any questions or concerns about the humidity setting on your CPAP machine, be sure to consult with your doctor or sleep therapist.
Troubleshooting Humidity Issues
Understanding Humidity Settings
The Airsense 11 humidifier includes three humidity settings: No Humidity, Fixed Humidity, and Auto Humidity. Auto Humidity automatically adjusts the humidity level based on the ambient temperature and airflow.
Adjusting Humidity Level in Auto Mode
To enable Auto Humidity, access the humidifier settings menu on your CPAP machine. The machine will automatically regulate the humidity level, providing a comfortable and effective breathing experience.
Resolving Auto Humidity Problems
If you experience issues with Auto Humidity, consider the following troubleshooting steps:
1. Checking the Water Tank: Ensure the water tank is filled and properly installed. An empty tank will prevent humidification.
2. Inspecting the Humidifier Chamber: Remove the humidifier chamber and inspect it for any leaks or obstructions. Clean or replace the chamber if necessary.
3. Resetting the CPAP Machine: Turn off the machine, unplug it for a few seconds, and then plug it back in. This may resolve any software glitches.
4. Adjusting the Room Temperature: Auto Humidity works best in rooms with temperatures between 60-80°F (15-27°C). If the room is too cold or hot, it may affect humidity levels.
5. Checking the Climate Control System: Ensure the humidifier is not competing with other moisture-producing appliances such as a humidifier or dehumidifier.
6. Inspecting the Air Filter: A dirty air filter can restrict airflow and impact humidity levels. Clean or replace the filter as needed.
7. Contacting the Manufacturer: If none of the above steps resolve the issue, contact the manufacturer of your CPAP machine for further assistance or replacement parts.
Error Code | Possible Cause | Solution |
---|---|---|
E-10 | Communication Error | Reset the device by unplugging and plugging it back in. If the error persists, contact the manufacturer. |
Utilizing the On-Board Humidifier
The AirSense 11 AutoSet can be equipped with a built-in humidifier to provide supplemental moisture to the therapy air. This can help alleviate dryness in the nose, throat, and sinuses, especially during cold or dry seasons. Here’s how to activate and use the on-board humidifier:
1. Ensure that the humidifier is filled with distilled water up to the maximum fill line.
2. Connect the humidifier to the AirSense 11 device and turn on the machine.
3. Press the “Humid” button on the LCD screen to enable the humidifier.
4. Use the arrow keys to adjust the humidity level from 0 (off) to 8 (max).
5. Monitor the humidity indicator on the LCD screen to ensure it’s within your desired comfort level.
6. To turn off the humidifier, press the “Humid” button again or set the humidity level to 0.
7. Regularly check the humidifier water level and refill it as needed to maintain optimal performance.
8. For advanced settings, such as automatic humidity adjustment based on ambient temperature and altitude, consult the device manual or refer to the table below:
Setting | Description |
---|---|
Auto | Adjusts humidity automatically based on ambient temperature and altitude. |
Fixed | Maintains a constant humidity level regardless of environmental conditions. |
Off | Disables the humidifier. |
Ensuring Proper Device Setup
To ensure the best performance from your AirSense 11 device, it’s crucial to set it up correctly. Here’s a step-by-step guide to ensure proper setup:
1. Unpack the Device and Accessories
Remove the device and accessories from the packaging and inspect them for any damage.
2. Attach the HumidAir Tubing
Connect the blue HumidAir tubing to the HumidAir outlet on the back of the device.
3. Attach the HumidAir Humidifier
Insert the HumidAir humidifier into the HumidAir tubing and turn it clockwise to secure it.
4. Fill the HumidAir Humidifier
Remove the water tank from the humidifier and fill it with distilled or purified water. Reattach the water tank.
5. Attach the Mask to the Tubing
Connect the mask to the opposite end of the HumidAir tubing.
6. Adjust the Mask
Put on the mask and adjust the straps to ensure a comfortable fit. Avoid overtightening the straps.
7. Power On the Device
Plug the device into a power outlet and press the power button.
8. Set the Auto Humidity Setting
Navigate to the “My Options” menu on the device screen and select “Humidity Settings.” Choose “Auto” to enable the auto humidity setting.
9. Detailed Explanation of Humidity Settings
The AirSense 11 offers three humidity settings:
Setting | Description |
---|---|
Fixed | Maintains a constant humidity level throughout the night. |
Auto | Automatically adjusts humidity based on room temperature and breathing patterns. |
Off | Disables humidification. |
For most users, the “Auto” setting is recommended as it provides personalized humidification levels that adapt to changing conditions.
Optimizing Sleep Quality with Auto Humidity
What is Auto Humidity?
Auto Humidity is a feature of the Airsense 11 CPAP machine that automatically adjusts the humidity level based on the user’s breathing patterns and the ambient environment. This provides optimal comfort and therapeutic benefits throughout the night.
Benefits of Auto Humidity
- Reduced nasal dryness and congestion
- Improved sleep quality
- Reduced rainout
- Enhanced adherence to CPAP therapy
How to Turn on Auto Humidity
- Access the Clinical Menu on your Airsense 11 device.
- Scroll down to “Humidification.”
- Select “Auto Humidity.”
- Choose the desired humidity level range (Recommended: 4-8).
- Confirm your settings.
Advanced Auto Humidity Settings
For optimal customization, the Airsense 11 offers advanced Auto Humidity settings. These include:
Setting | Description |
---|---|
Auto Humidity Response | Adjusts the humidity response time based on breathing patterns. |
Adaptive Humidification | Learns and adapts to the user’s breathing patterns over time. |
Heated Tube Temperature | Controls the temperature of the heated tube to reduce rainout. |
Additional Tips
- Use distilled water in the humidifier chamber to prevent mineral buildup.
- Clean the humidifier chamber and water tub regularly to maintain hygiene.
- If you experience excessive rainout, adjust the heated tube temperature or consult your healthcare provider.
Conclusion
Auto Humidity is a valuable feature that can significantly enhance the comfort and effectiveness of CPAP therapy. By automatically adjusting humidity levels, the Airsense 11 CPAP machine provides optimal sleep conditions, reducing nasal dryness, improving sleep quality, and promoting adherence to therapy.
How To Turn Airsense 11 To Auto Humidity Setting
The AirSense 11 is a popular CPAP machine that offers a variety of features to make it comfortable to use. One of these features is the ability to automatically adjust the humidity level of the air that is delivered to the user. This can be helpful for people who experience dry mouth or nasal congestion during CPAP therapy.
To turn on the Auto Humidity setting, first, make sure that the humidifier is attached to the CPAP machine. Then, press the Menu button on the front of the machine. Use the arrow keys to navigate to the Humidification menu and press the Select button. Then, use the arrow keys to navigate to the Auto Humidity setting and press the Select button. The machine will now automatically adjust the humidity level based on the user’s breathing patterns.
The Auto Humidity setting can be a helpful way to improve the comfort of CPAP therapy. However, it is important to note that this setting may not be suitable for everyone. People who have a history of respiratory problems should talk to their doctor before using the Auto Humidity setting.
People Also Ask
How do I turn off the Auto Humidity setting on the AirSense 11?
To turn off the Auto Humidity setting, follow the same steps as above but select the Off option instead of the Auto Humidity option.
What is the best humidity setting for CPAP?
The best humidity setting for CPAP will vary from person to person. Some people find that a lower humidity setting is more comfortable, while others prefer a higher humidity setting. It is important to experiment with different settings to find what works best for you.
Can I use the AirSense 11 without the humidifier?
Yes, you can use the AirSense 11 without the humidifier. However, it is important to note that this may make the therapy less comfortable. If you experience dry mouth or nasal congestion, you may want to try using the humidifier.